So if you need one for online use this is not the unit to buy. The device I purchased is an OFFLINE ONLY version of micropod 2, but I only use it for diagnostics, not for programming as I do not have a TechAuthority account. Once updated, disconnect the internet and change the date back to 1/1/17 for it to work. So the instructions are good, but at least for me, I had to fix the date to the correct date to get the flexnet updates. Plugged in the pod, waited for windows to see it and make the virtual network, and then launched wiTech. Then I followed the rest of the instructions. As soon as both had updated, I disconnected internet and then changed date back to 1/1/17. Now flexnet connect worked and I was able to update K-line and enhanced drb3. So I changed the date to the correct date. Windows update also errored because of the wrong date. Try to use flexnet connect to update but it failed. In the beginning when installing the stubs, his directions had already instructed you to change the date to 1/1/17, then navigate to the folder and install the three stubs. In order to get it to work, I had to change the date. I had to change it up since I did follow his instructions exactly, but the flexnet update didn't work, and so it failed and the drb3 did not work. Anyway I will have to contact the seller and arrange for some discount since the hard drive is virtually useless.Īnyway, the main thing is that the miocropod 2 had the required circuits etc, and the DRB3 works after following most of Radius's instructions. I was able to make a backup though and there is actually a second partition on it with an Acronis backup image already created from 8/15/17.

Its making beeping sounds and clicking and on its very last legs. It came with a hard drive that is barely working.

I bought my miocropod 2 clone from .uk same as what Radius bought. Go on using wiTech MicroPod 2 to diagnose or program Chrysler. Tick off " Offline work" at the left corner of screen, then you don't need to login. If it still display message" an internal registration error has occurred ", just close this windows to ignore it. Find out "VerificationHash", then the followed "Value", change the first number to any value i.e change 6 to any number between 1-9. Enter C:/Program Files (x86)/DCC Tools/wiTECH/client. Right click Witech Diagnostic Application-> Properties->Open file locationĢ. Please check the knowledgeīase to determine how to register a device"ġ. Device with serial number*** is not registered.